Jual RCD Tester KEW Kyoritsu Model 5410

Deskripsi

Distributor Jual RCD Tester KEW Kyoritsu Model 5410

RCD Tester Jual RCD Tester KEW Kyoritsu Model 5410

kew_head Jual RCD Tester KEW Kyoritsu Model 5410

5410

 
 
 
Measurement of RCD trip time
Conducting testing of rated residual non-operating currents at × 1/2 Range, measuring RCD trip time at × 1 and × 5 Ranges.
Measurement of trip out current
Measuring trip out current by varying current automatically.
Remote Test
Enabling a user to hold the Test Leads with his both hands by locking the Test Button. Measurement will automatically start when the main voltage is detected.
Voltage Measurement
Carrying out a constant measurement of voltage in the stand-by mode at each Range.
5410 Jual RCD Tester KEW Kyoritsu Model 5410
ce Jual RCD Tester KEW Kyoritsu Model 5410
Auto-detection of Contact voltage
Detecting the voltage to earth of Earth electrodes or Protective conductors during RCD test – when applying test currents – at measurement using EARTH in order to prevent electrical shocks caused by the damaged earth. Measurement will be ceased at AC50V or more.
Dust- and Water-proof
Dust- and Water-proof construction (designed to IEC 60529 IP54).
Backlight
Facilitating working at dimly illuminated locations.
spacer Jual RCD Tester KEW Kyoritsu Model 5410

Gate Valve Tozen CGV-J 10K

https://flowmeterjakarta.com/product/water-meter-magnos-dn-100/

spacer Jual RCD Tester KEW Kyoritsu Model 5410

 
Measurement of RCD trip time – Measurement of trip out current
Range ×5 ×1 ×1/2 AUTO RAMP (mA)
Rated Voltage 100V±10%
200V+32%/-10%
400V±10%
(50/60Hz)
Test current 15/30/50/100mA 15/30/50/100/200/500mA 15/30/50/100/200/500mA
Measuring range Testing time
200ms
Testing time
2000ms
Testing time
2000ms
40%~110% of lΔn
(goes up by 5%)
Testing time
300ms × 15steps
Accuracy
(Trip Time)
|±1%rdg±3dgt |±1%rdg±3dgt |±1%rdg±3dgt Test Current
at each step
-4%~+4%
Accuracy
(Test Current)
|+2%~+8%dgt |+2%~+8%dgt |-8%~-2%dgt
Voltage Measurement
Measuring range 80V~450V (50/60Hz)
Accuracy |±2%rdg±4dgt
 
Applicable Standard IEC 61010-1 Pollution degree2 CAT.III 300V / CAT.II 400V
IEC 61010-031
IEC 61557-1, 6
IEC 60529 (IP54)
Display 1999 counts (3 1/2digits), Large LCD
Operating temperature & humidity 0ºC~40ºC, relative humidity 85% (no condensation)
Storage temperature & humidity -20ºC~60ºC, relative humidity 85% (no condensation)
Withstand Voltage AC3700V / 1 min. (between electrical circuit and enclosure)
Insulation resistance 50MΩ or more / 1000V (between electrical circuit and enclosure)
Sleep Function
(1) Automatically enters Sleep mode in 3 minutes after the last switch operation (current consumption 75µA). This function doesn’t work at voltage measurements. To exit from the Sleep mode, set the Function switch to OFF position once, and re-set it to the Range at which a measurement to be conducted.
(2) Backlight turns off in 1 minute after it lights up.
Power Source DC 12V / Size AA battery R6P (SUM-3) × 8 pcs.
Dimension 186(L)×167(W)×89(D)mm
Weight Approx. 965g (including batteries)
Possible number of Measurements 1200 times or more
(measure every 30 seconds at ×1/2 Range, lΔn=100mA)
Accessories 7128A (Test leads)
7129A (Test lead with alligator clip)
8017 (Long pin) × 2
Cord case, Strap belt, Instruction manual,
Size AA battery R6P(SUM-3)×8pcs.

Reviews

There are no reviews yet.

Be the first to review “Jual RCD Tester KEW Kyoritsu Model 5410”