CAL2K Features
FEATURE | DESCRIPTION |
Easy to maintain | Easy to maintain, self system test for technicians. |
Compact Size. Fits Almost Anywhere. | Compact Size – able to fit more systems into a standard laboratory. |
Fully Automatic Operation. | Fully automatic operation – temperature readings and calculations are done for you. |
Network up to 7 Calorimeters | Possible to network up to 7 calorimeters. |
Rapid. Accurate. | Rapid and accurate determinations. |
10 Samples Per Hour | 10 samples per hour using the CAL2K Cooler and 2 Bomb Vessels. |
Waterless Vessel | Isothermal design using a waterless patented vessel. No bucket, no spillage, no measuring. |
More Memory. More Determinations. | Large memory for storing more than 2000 determinations, including operating conditions and user statistics. |
Automatic Correction | Automatic correction for firing wire, cotton, spikes, etc. |
Automatic Calibration | Fully automatic calibration, with 10 calibrations per vessel for standard deviation. |
Calibrated Sensors | Calibrated sensors built into vessel wall. |
Optional Spiking | Can use spiking for hard to combust samples. |
Intelligent “SMART” Vessel | Intelligent SMART vessel with fault diagnostics and calorific processor. |
Pre-Programmed Vessel | Vessels are pre-programmed for 5000 determination cycles before inspection. |
Firing Limits | Adjustable firing limits set per vessel. |
High and Low Mass Limits | |
Determination Cycle Adjustment | |
Precise and reproducible determination of gross calorific values according to ISO 1928, DIN 51900 and BS1016:105. |
CAL2K Technical Specifications
TECHNICAL SPECIFICATIONS | DESCRIPTION |
Connectivity | Multi-drop RS232 port at 9.6KB |
LIMS | No |
Mass HEAP | Yes |
Balance Interface | Yes, at 2.4KB |
Result Memory | 2048 records, 131KB |
Temperature Resolution | 0.000’01°C |
Display | 4 x 40 character LCD |
Keyboard | Limited, front panel, no ASKII, onboard |
Sample ID | 6 characters |
Group ID | 8 characters |
Vessel Record | No |
Real Time | Yes |
Chassis Identification | No |
Calibration | Normal replace, single or multiple |
History Calibration | No |
Units | KJ, BTU, CAL |
Result Compensation | No |
Result Validation | No |
Vessel Pressure Monitor | No |
Oxygen Filling | External Manual Filling Station |
De-Filling | Manual |
Max Chassis Recording | – |
Chassis Name | No |
Password Protection | User Security Manager Password, PC Password |
Network Multiple Calorimeters | Yes, up to 7 x CAL2K |
Vessel Leak Monitor | No |
Event Storage | No |
Event Types | – |
Event Classification | – |
Vessel Interchange | No |
Vessel Lockout, Lock-in | No |
Sample Repeat Speed | 7-8min |
Operator Time Per Test | 2min |
Cooling | Water |
Cooling Modes | – |
RSD | 0.1 |
Power Consumption | 0-264 VAC 50/60Hz 5W |
Power Supply | External 9V |
Water Consumption | Yes, re-circulating |
Repeatability | 0.1% |
Calorimeter Type | Static Jacket (Isothermal) |
Number of Vessels | Unlimited (10+) |
Closure Type | Screw Cap |
Tests per hour with 2 vessels | 10 |
Bomb Vessel Type | Removable |
Oxygen Filling | Semi-Automatic |
Bomb Vessel Washing | Manual |
Printer Connection | RS232 |
Balance Connection | RS232 |
Environmental | 10-40°C |
Printing of Results | Via PC Software |
PC Software | Advanced |
Correction Factors | 2 |
Mass Entry | Auto & Manual |
CE/TUV Certificate | Yes |
Vessel Determinations | 5000 |
Spiking | Yes |
Self Testing | No |