Deskripsi
CAL2K Features
| FEATURE | DESCRIPTION | 
| Easy to maintain | Easy to maintain, self system test for technicians. | 
| Compact Size. Fits Almost Anywhere. | Compact Size – able to fit more systems into a standard laboratory. | 
| Fully Automatic Operation. | Fully automatic operation – temperature readings and calculations are done for you. | 
| Network up to 7 Calorimeters | Possible to network up to 7 calorimeters. | 
| Rapid. Accurate. | Rapid and accurate determinations. | 
| 10 Samples Per Hour | 10 samples per hour using the CAL2K Cooler and 2 Bomb Vessels. | 
| Waterless Vessel | Isothermal design using a waterless patented vessel. No bucket, no spillage, no measuring. | 
| More Memory. More Determinations. | Large memory for storing more than 2000 determinations, including operating conditions and user statistics. | 
| Automatic Correction | Automatic correction for firing wire, cotton, spikes, etc. | 
| Automatic Calibration | Fully automatic calibration, with 10 calibrations per vessel for standard deviation. | 
| Calibrated Sensors | Calibrated sensors built into vessel wall. | 
| Optional Spiking | Can use spiking for hard to combust samples. | 
| Intelligent “SMART” Vessel | Intelligent SMART vessel with fault diagnostics and calorific processor. | 
| Pre-Programmed Vessel | Vessels are pre-programmed for 5000 determination cycles before inspection. | 
| Firing Limits | Adjustable firing limits set per vessel. | 
| High and Low Mass Limits | |
| Determination Cycle Adjustment | |
| Precise and reproducible determination of gross calorific values according to ISO 1928, DIN 51900 and BS1016:105. | 
CAL2K Technical Specifications
| TECHNICAL SPECIFICATIONS | DESCRIPTION | 
| Connectivity | Multi-drop RS232 port at 9.6KB | 
| LIMS | No | 
| Mass HEAP | Yes | 
| Balance Interface | Yes, at 2.4KB | 
| Result Memory | 2048 records, 131KB | 
| Temperature Resolution | 0.000’01°C | 
| Display | 4 x 40 character LCD | 
| Keyboard | Limited, front panel, no ASKII, onboard | 
| Sample ID | 6 characters | 
| Group ID | 8 characters | 
| Vessel Record | No | 
| Real Time | Yes | 
| Chassis Identification | No | 
| Calibration | Normal replace, single or multiple | 
| History Calibration | No | 
| Units | KJ, BTU, CAL | 
| Result Compensation | No | 
| Result Validation | No | 
| Vessel Pressure Monitor | No | 
| Oxygen Filling | External Manual Filling Station | 
| De-Filling | Manual | 
| Max Chassis Recording | – | 
| Chassis Name | No | 
| Password Protection | User Security Manager Password, PC Password | 
| Network Multiple Calorimeters | Yes, up to 7 x CAL2K | 
| Vessel Leak Monitor | No | 
| Event Storage | No | 
| Event Types | – | 
| Event Classification | – | 
| Vessel Interchange | No | 
| Vessel Lockout, Lock-in | No | 
| Sample Repeat Speed | 7-8min | 
| Operator Time Per Test | 2min | 
| Cooling | Water | 
| Cooling Modes | – | 
| RSD | 0.1 | 
| Power Consumption | 0-264 VAC 50/60Hz 5W | 
| Power Supply | External 9V | 
| Water Consumption | Yes, re-circulating | 
| Repeatability | 0.1% | 
| Calorimeter Type | Static Jacket (Isothermal) | 
| Number of Vessels | Unlimited (10+) | 
| Closure Type | Screw Cap | 
| Tests per hour with 2 vessels | 10 | 
| Bomb Vessel Type | Removable | 
| Oxygen Filling | Semi-Automatic | 
| Bomb Vessel Washing | Manual | 
| Printer Connection | RS232 | 
| Balance Connection | RS232 | 
| Environmental | 10-40°C | 
| Printing of Results | Via PC Software | 
| PC Software | Advanced | 
| Correction Factors | 2 | 
| Mass Entry | Auto & Manual | 
| CE/TUV Certificate | Yes | 
| Vessel Determinations | 5000 | 
| Spiking | Yes | 
| Self Testing | No | 
 
								 
								 
								 
								




Reviews
There are no reviews yet.