Jual Lutron PH Meter PH208/PE03

Deskripsi

DistributorJual Lutron PH Meter PH208/PE03

FEATURES Jual Lutron PH Meter PH208/PE03
* Professional PH/mV METER.
PH range : 0 to 14 PH x 0.01 PH.
mV range : -1999 mV to 1999 mV.
* Used the optional ORP probe to become a professional ORP meter.
*Wide manual temperature compensation adjustment can be
operated by push button on the front panel easily.
* Calibration for pH 7, pH 4 and pH 10 by push button.
* Temperature compensation of pH function can be done by optional
ATC (Automatic Temperature Compensation) probe.
* Auto shut off saves battery life.
* Memorize Max./Min. reading with recall.
* Data hold.
* RS232 computer interface.

* Records Maximum and Minimum readings with recall.
* Data hold.

* The instrument is with mV ( millivolt ) function for mV measurement
( Be plugged with optional ORP probe ORP-04 to be a professional ORP meter)
* Powered by 006P DC 9V battery.
* ℃ or ℉ can be converted by push button on the front panel.
* pH calibration is easily to be done by push button on the front panel

* Optional ATC (Automatic Temp. Compensation) probe is available for pH measurement.
* Using the durable, long-lasting components and a strong lightweight ABS-plastic housing case.
* Microprocessor circuit assures high accuracy and reliable performance.
* pH function with high input impedance avoids measuring error.
* Large LCD, dual function display. * Wide applications: water conditioning,
aquariums, beverage…

GENERAL SPECIFICATIONS

Display 51 mm x 32 mm, dual function LCD display, 15 mm ( 0.6″ ) digit size.
Measurement pH : 0 to 14 pHmV : -1999 mV to 1999 mV
Input Impedance 10^12 ohm
Temperature Compensationfor pH measurement Manual : 0 to 100 ℃, be adjusted by push button on front panel.Automatic (ATC) : With the optional TEMP. probe ( TP-07 ) 0 to 65 ℃.
pH Calibration pH7, pH4, and pH10, 3 points calibration ensure the best linearity and accuracy.
Power off Auto shut off saves battery life, or manual off by push button.
Data Output RS 232 computer serial interface.
pH Temp. Compensation build thermister Temp. sensor for ( ATC )
Data Hold Hold the reading value on the display.
Memory Recall Maximum & Minimum value reading values can be saved and retrieved by record function.
Sampling Time Approx. 0.8 second.
Overload indication “- – – -” symbol on the display
pH Electrode Optional, Any pH electrode with BNC connector.
Circuit Custom one-chip of microprocessor LSI circuit.
Operating Temperature 0 ℃ to 50 ℃(32 ℉ to 122 ℉).
Operating Humidity Max. 80% RH.
Power Supply 006P DC 9V battery (Optional) ( Alkaline or Heavy duty type ).
Power Current Approx. DC 7 mA.
Size ( meter ) 195 x 68 x 30 mm ( 7.6 x 2.6 x 1.2 inch ).
Weight 250 g/0.55 LB ( battery included ).
Power off Auto power shut off to save battery life.
Standard Accessories Instruction Manual……………………….. 1 PC
Optional Probes & Accessories pH electrodes :* General purpose pH electrode, PE-03.* General purpose pH electrode, PE-11.

* Professional pH electrode, PE-01.

* Spear tip pH electrode, PE-06HD, PE-04HD.

* Glass body plane pH electrode, PE-08.

* Glass body professional pH electrode, PE-02.

ATC temp. probe, TP-07

pH electrodes + Temp. Probe, PE-03K7

ORP electrode, ORP-14

Hard carrying case, CA-06

RS232 cable, UPCB-02

USB cable, USB-01

Application Software, SW-U801-WIN

ELECTRICAL SPECIFICATIONS ( 23 ±5 ℃ )

pH meter specifications

Measurement Measuring Range Resolution Accuracy
pH 0 to 14 pH

0.01 pH

± (0.02 pH + 2 d) * Meter only
mV -1999 mV to 1999 mV 1 mV ± (0.5% + 2 d) * Meter only

Temperature Compensation for pH measurement :

* Manual : 0 to 100 ℃, be adjusted by push button on front panel.
* Automatic ( ATC ) : With the optional TEMP. probe ( TP-07 ) 0 to 65 ℃.

pH Calibration :

* pH7, pH4, and pH10, 3 points calibration ensure the best linearity and accuracy.

 

OPTIONAL ACCESSORIES

PE-01 pH Electrode, 0-14 pH. pH-07 pH 7.00 standard buffer solution.
PE-03 pH Electrode, 1-13 pH (Typical 0 to 14 pH). PE-03K7 pH Electrode + Temp. probe
PE-11 pH Electrode, 1-13 pH (Typical 0 to 14 pH). CA-06 HARD CARRYING CASE.
PE-04HD Spear Tip pH Electrode, 0-14 pH.Penetration electrode for soil, meat, cheese… ORP-14 ORP Electrode.
TP-07 Automatic Temp. Compensation probe.
PE-06HD Spear Tip pH Electrode, 0-13 pH..Penetration electrode for soil, meat, cheese… SW-U801-WIN Software for Data Logging.
UPCB-02 RS232 cable for data transmission.
PH-04 pH 4.00 standard buffer solution. USB-01 USB cable for data transmission.

Actuator Siemens SKP 15.000E2

https://flowmeterjakarta.com/product/jual-water-meter-itron-woltmag-dn-50-100/

 

APPLICATIONS

* AQUARIUMS * FOOD PROCESSING * PAPER INDUSTRY * SCHOOLS & COLLEGES
* BEVERAGE * PHOTOGRAPHY * PLATING INDUSTRY * SWIMMING POOLS
* FISH HATCHERIES * LABORATORY * QUALITY CONTROL * WATER CONDITIONING

Reviews

There are no reviews yet.

Be the first to review “Jual Lutron PH Meter PH208/PE03”