JUAL KROHNE OPTIFLUX 4000

krohne optiflux 4000 suatu alat ukur yang diguanakan untuk mengukur laju air serta volume air pada jaringan perpipaan untuk melayani pemakai baik perorangan ataupun perusahaan dengan memperhatikan aspek teknis dan non teknis, sehingga masayarakat atau perusahaan dapat dengan mudah memperloeh air dalam jumlah tertentu, kwalitas sesuai dengan persayaratan air bagi kesehatan ataupun sesuai dengan kebutuhannya.

Deskripsi

JUAL KROHNE OPTIFLUX 4000


Distributor KROHNE OPTIFLUX 4000 / Spesifikasi KROHNE OPTIFLUX 4000

Electromagnetic flow sensor
• Robust, fully welded construction
• Standard solutions for the widest range of industrial applications
• Engineered solutions for very demanding applications

Measuring system
Measuring principle : Faraday’s law
Application range : Electrically conductive fluids
Measured value
Primary measured value : Flow velocity
Secondary measured value : Volume flow
Design
Features :

Fully welded maintenance-free sensor.
Flange version with full bore flow tube.
Standard as well as higher pressure ratings.
Broad range of nominal sizes.
Industry specific insertion lengths.
Modular construction : The measurement system consists of a flow sensor and a signalconverter. It is available as compact and as separate version.
Compact version:

With IFC 040 converter: OPTIFLUX 4040 C
With IFC 100 converter: OPTIFLUX 4100 C
With IFC 300 converter: OPTIFLUX 4300 C

Remote version :

In wall (W) mount version with IFC 100 converter : OPTIFLUX 4100 W
In field (F), wall (W) or rack (R) mount version with IFC 300 converter:
OPTIFLUX 4300 F, W or R

Nominal diameter :

With IFC 040 converter: DN10… 150 / 3/8… 6″
With IFC 100 converter: DN2.5…1200 / 1/10…48″
With IFC 300 converter: DN2.5…3000 / 1/10…120″

Measuring accuracy
Reference conditions

Medium : water
Temperature : 10…30°C / 50…86°F
Operating pressure : 1 bar / 14.5 psig
Inlet section : ≥ 5 DN
Electrical conductivity : ≥ 300 μS/cm
Flow conditions similar to EN 29104

Maximum measuring error :

These values are related to the pulse / frequency output.
Related to volume flow (MV = Measured Value)
With IFC 040 converter:
v < 1 m/s / 3.3 ft/s: ± 5 mm/s
v > 1 m/s / 3.3 ft/s: ± 0.5 % of MV
With IFC 100 converter:
DN2.5…6: ± 0.4% of MV + 1 mm/s
DN10…1200: ± 0.3% of MV + 1 mm/s
With IFC 300 converter:
DN2.5…6: ± 0.3% of MV + 2 mm/s
DN10…1600: ± 0.2% of MV + 1 mm/s
DN1800…3000: ± 0.3% of MV + 2 mm/s
The additional typical measuring deviation for the
current output is ±10 μA.
The maximum measuring error depends on the installation
conditions.
For detailed information refer to Measurement accuracy on page 21

Repeatability : ±0.1% of MV, minimum 1 mm/s
Calibration / Verification

Standard:
Wet calibrated on EN 17025 accredited calibration rig by direct
volume comparison.
Optional:
Verification to Measurement Instrument Directive (MID),
Annex MI-001.
Standard: Verification at Ratio (Q3/Q1) = 80, Q3 ≥ 2 m/s
Optional: Verification at Ratio (Q3/Q1) > 80 on request
(Only in combination with IFC 300)
Long term stability : ±0.1% of MV
Special calibration : On request.
MID Annex MI-001 (Directive 2004/22/EC):
EC-Type examination certificate to MID Annex MI-001
(Only in combination with IFC 300)
Diameter range: DN25…500
Forward and reverse (bi-directional) flow
Liquid temperature range: +0.1°C / 50°C
For detailed information refer to Legal metrology on page 15

OIML R49

Certificate of conformity to OIML R49 : (Only in combination with IFC 300) JUAL KROHNE OPTIFLUX 4000

Diameter range

Class 1: DN80…500
Class 2: DN25…50
Forward and reverse (bi-directional) flow
Liquid temperature range: +0.1°C / 50°C

 